| Bin Diameter (nominal ft.) | 9' | 9 | 9' | 12' | 12' | 15' | 15' | 15' | 15' | 18' | 18' | 18' | 18' | 21' | 21' | 21' | 21' | 21' | 21' | 24' | 24' | 24' | 24' | 24' | 24' | 24' | 
| Number of rings | 1 | 2 | 3 | 2 | 3 | 2 | 3 | 4 | 5 | 3 | 4 | 5 | 6 | 4 | 5 | 6 | 7 | 8 | 9 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 
| Number of body sheets per ring | 3 | 3 | 3 | 4 | 4 | 5 | 5 | 5 | 5 | 6 | 6 | 6 | 6 | 7 | 7 | 7 | 7 | 7 | 7 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 
| Storage Capacity (bushels) | 330 | 520 | 720 | 1020 | 1360 | 1660 | 2200 | 2740 | 3290 | 3340 | 4120 | 4900 | 5680 | 5700 | 6760 | 7820 | 8880 | 9940 | 11000 | 7930 | 9320 | 10700 | 12090 | 13470 | 14860 | 16250 | 
| Overall Bin Height w/o skid – Reg Hopper (add 4" for skid) | 12'-10" | 16'-6" | 20'2" | 18'-5" | 22'-1" | 20'-2" | 23'-10" | 27'-6" | 31'-2" | 26'-4" | 30'-0" | 33'-8" | 37'-4" | 32'-10" | 36'-6" | 40'-2" | 43'-10" | 47'-6" | 51'-2" | 34'-9" | 38'-5" | 42'-1" | 45'-9" | 49'-5" | 53'-1" | 56'-9" | 
| Overall Bin Height w/o skid – LP Hopper (add 4" for skid) | NA | NA | NA | NA | NA | 18'-11" | 22'-7" | 26'-3" | 29'-11" | 24'-11" | 28'-7" | 32'-3" | 35'-11" | 30'-10" | 34'-6" | 38'-2' | 41'-10" | 45'-6" | 49'-2" | 32'-9" | 36'-5" | 40'-1" | 43'-9" | 47'-5" | 51'-1" | 54'-9" | 
| Clearance under gate – Regular Hopper | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 18" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 24" | 
| Clearance under gate – Low Profile Hopper | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 0" | 
| Minimum Auger Length – Reg Hopper (*check auger specs) | 21' | 27' | 32' | 30' | 35' | 32' | 38' | 44' | 50' | 42' | 48' | 53' | 59' | 52' | 58' | 63' | 69' | 75' | 80' | 55' | 61' | 66' | 72' | 78' | 83' | 89' | 
| Minimum Auger Length – LP Hopper(*check auger specs) | NA | NA | NA | NA | NA | 30' | 36' | 42' | 47' | 40' | 45' | 51' | 57' | 49' | 55' | 60' | 66' | 72' | 77' | 52' | 58' | 63' | 69' | 75' | 80' | 86' | 
| Bin Wall & Roof Construction |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Material – High tensile steel – minimum 40,000 psi yield | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Roof slope | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 
| Stiffeners | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 
| Lid – Remote open (only) – locks in open and closed positions | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Lid – Remote open & swivel – allows auger entry from any angle | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Ladder – Safer, wider, 16" rung | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Hoppers |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Number of legs | <4 | 4 | 4 | 6 | 6 | 8 | 8 | 8 | 8 | 10 | 10 | 10 | 10 | 14 | 14 | 14 | 14 | 14 | 14 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 
| Legs around perimeter – Stronger, more stable. | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Stronger leg frame – Less legs for better unloading access | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Standard hopper angle – Degrees | <42 | 42 | 42 | <42 | 42 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 
| Optional hopper angle – up to 55 degrees | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Regular profile hopper – Requires unloading hopper | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Low profile hopper – Built in auger boot doesn't require hopper | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Gate drip collar – Keeps moisture away from gate | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Access hatch (manhole) – Standard | O | O | O | O | O | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Slide gate – Mounts in 4 positions @ quarter turn increments | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Rack and pinion opener | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Nylon roller bearings | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Stronger uni-cone design – not segmented | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Skids |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Circular design is stronger and more stable | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Number of rings in skid | <1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 | 3 | NA | NA | NA | NA | 3 | NA | NA | NA | NA | NA | NA | 
| Welded to bin standard or bolted on request | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Finish |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Surface preparation – Sand-buff, degrease-wash, inspected | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Bin – Galfan – Lasts longer, stays better looking than galvanized | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Hopper – Self priming high build industrial alkyd enamel | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Venting |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| 15"x 15" roof vents / 22" circular | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Aeration |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Perforated pipe in hopper | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Aeration adapter – Round to square transition | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Compatible with Edwards aeration systems | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 
| Accessories |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Bin level indicator | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Screw-in ground anchor | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | O | 
| Warranty |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| 1 year. Extended to 5 years upon receipt of registration card | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Warranty qualification – subject to proper site prep. & constr. | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Warranty if non PSP products & access. used – call PSP |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Delivery |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| All costs are FOB Clavet, SK | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Delivered to customers site | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| Drop charge for multiple site drops | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 
| Site unloading requirement – None if PSP delivers | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | 
| On Site Construction |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 
| Construction cost extra – customer deals direct with contractor | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S | S |